Technical Specifications

WXQ300 Series — Complete Technical Reference

Core Technical Parameters

Parameter Value / Description
Output Frequency 0-600Hz
Overload Capacity 150% rated current 1min, 180% rated current 3s
Modulation Type Optimized space voltage vector (SVPWM) modulation
Control Mode Sensorless vector control (with optimized low-frequency dead-zone compensation)
Frequency Resolution Digital setting: 0.01Hz; Analog setting: Max frequency × 0.025%
Starting Frequency 0.0-10.0Hz
Torque Boost Auto torque boost, Manual torque boost 0.1%-30.0%
Built-in PID Easy to constitute closed-loop control system
Multi-Speed Operation Via built-in PLC or control terminal, multi-speed operation can be achieved
Running Command Channel Control panel reference, Control terminal reference, 485 communication
Digital Input Channel Forward/reverse instructions: 5 programmable digital inputs
Analog Input Channel 1 channel analog signal input, 0-20mA, 0-10V
Analog Output Channel 4-20mA or 0-10V selectable, can realize setting frequency output, etc.
Relay Output Channel 2 channels of relay output signal
Protection Function Over-current, Over-voltage, Under-voltage, Over-heat, Overload, Short-circuit
PV Power Tracking CVT mode, MPPT mode

Control Panel Specifications

Standard Panel

  • Panel Dimensions: 85mm × 58mm
  • Display: Dual Line, Red Digit LED Display
  • Keys: PRG, Arrows, FUNC, ENT
  • Buttons: RUN & STOP
  • Cutout Size: 99mm × 68mm
SHZK VFD technical specification

Enhanced Panel

  • Panel Dimensions: 85mm × 58mm
  • Display: Dual Line LED Display (Upper: Set Value / Lower: Actual Value)
  • Keys: PRG, Shift, Up, Down, FUNC, ENT
  • Buttons: RUN & STOP
  • Feature: Remote Mountable with Extension Cable
SHZK VFD technical specification

Main Circuit Terminals

Terminal Label Name Description
R/L1, S/L2, T/L3 Power Input Terminals Connect to AC power source points
PP, PB Brake Resistor Connection Connect to the brake resistor
U, V, W Inverter Output Terminals Connect to three-phase motor
U, V (H2) Inverter Output Terminals Connect to single-phase motor
⏚ Ground Ground Terminal Connect to power distribution box ground terminal or other regulated grounding points

Control Terminal Function Description

Category Terminal Name Function Description
Power +10V-GND External +10V Provides +10V power supply, max output current 50mA. Used as external potentiometer power supply (1kΩ-5kΩ)
+24V-GND External +24V Provides +24V power supply, used for digital I/O and external sensor, max 200mA
Analog Input AI1-GND Analog Input 1 Input range: DC 0-10V / 0-20mA; Input resistance: 22kΩ (voltage), 500Ω (current)
DI1~DI5-GND Digital Input 1-5 5 programmable digital input channels, voltage range: 5V-30V
Analog Output AO1-GND Analog Output 1 Output: 0-10V / 0-20mA
Relay Output T1A-T1C Relay 1 (NO) Contact capacity: AC250V/3A, DC30V/1A
T2A-T2C Relay 2 (NO) Contact capacity: AC250V/3A, DC30V/1A

6 Comprehensive Safety Protections

SHZK VFD technical specification

Over-Voltage Protection

Monitors DC bus voltage and shuts down when exceeding safe threshold

SHZK VFD technical specification

Under-Voltage Protection

Protects against power supply drop to prevent damage to components

SHZK VFD technical specification

Over-Current Protection

Limits output current to prevent IGBT damage during motor stall or overload

SHZK VFD technical specification

Over-Temperature Protection

Heat sink temperature monitoring with automatic frequency reduction

SHZK VFD technical specification

Phase Loss Protection

Detects input/output phase loss condition and triggers alarm

SHZK VFD technical specification

Short-Circuit Protection

Instant shutdown upon detecting output short-circuit to protect IGBT module

Electrical Installation Guide

⚠️ Signal Input Terminal Wiring Instructions

  • Use shielded cables for all signal wiring to prevent electromagnetic interference
  • Keep signal cable distance as short as possible
  • Separate signal cables from power cables
  • Under severe interference conditions, install filtering components
  • Connect shield layer to ground terminal at inverter side only (single-point grounding)
SHZK VFD technical specification
SHZK VFD technical specification

Need the right drive for your motor?

Tell us your power, voltage and application. Our engineers will size it and send a competitive factory quote within 24 hours.

Request a Quote