300N H2 Series

Key facts

  • Power range: 0.75 kW to 3 kW
  • Input: single-phase 220V (200-240V); output: single-phase 220V
  • Series name: SHZK 300N H2 (single-phase AC drive and speed controller)
  • Control: sensorless vector control (SVC) and V/F control, built-in PID and multi-speed / simple PLC
  • Communication: Modbus RTU over RS485; enclosure IP20 standard, IP54 optional
  • Certifications: CE (EU LVD 2014/35/EU and EMC 2014/30/EU), ISO 9001:2015, RoHS
  • OEM/ODM supported (logo, packaging, voltage, firmware); sample orders accepted
  • Factory: Yueqing, Zhejiang, China; contact mail@shzkvfd.com or WhatsApp +86 13757750205

300N H2 Series – Single Phase 220V Input / Single Phase 220V Output

The 300N H2 Series is a high-performance vector inverter designed for single-phase 220V input and single-phase 220V output applications. Ideal for small motor speed control with advanced SVPWM control technology.

Need a higher power rating? The 300N H2 Series standard range covers 0.75 kW to 3 kW. Larger ratings in this single-phase-input / single-phase-output configuration can also be built to order — contact our engineers with your motor rating, supply voltage and duty cycle for a quotation.

Key Features

  • Output Frequency: 0-500Hz
  • Overload Capacity: 150% rated current for 1 minute, 180% for 3 seconds
  • Control Method: Optimized SVPWM control
  • Control Mode: Sensorless vector control with optimal low-frequency dead zone compensation
  • Frequency Resolution: Digital 0.01Hz; Analog max frequency ×0.025%
  • Built-in PID closed-loop control
  • Multi-speed operation via built-in PLC or control terminals
  • RS485 communication support
  • 5 programmable digital inputs
  • 2 analog inputs (0-20mA, 0-10V)
  • 2 relay outputs
  • Comprehensive protection: overcurrent, overvoltage, undervoltage, overheat, overload

Model Specifications

Model Rated Current Dimensions (H×W×D mm) Shell Type
300N-0.75G-H2 Input 4.5A / Output 4A 165×98×128 Plastic (S)
300N-1.5G-H2 Input 8A / Output 7A 165×98×128 Plastic (S)
300N-2.2G-H2 Input 11A / Output 9.6A 165×98×128 Plastic (S)
300N-003G-H2 Input 14A / Output 12A 187×100×137.5 Plastic (S)

Y-Series Black Enclosure Option

The same 300 H2 Series (single-phase 220V to single-phase 220V) is also available in the Y-series black-enclosure variant with its own model lineup — identical electrical performance in a black-moulded housing. Ratings & dimensions below.

Model Rated Current Dimensions (H×W×D mm) Shell Type
300-0.75KWG-H2 In 3.5A / Out 3.5A 164×88×125 Plastic (Y Black)
300-1.5KWG-H2 In 6.8A / Out 6.8A 164×88×125 Plastic (Y Black)
300-2.2KWG-H2 In 10A / Out 10A 164×88×125 Plastic (Y Black)
300-3.0KWG-H2 In 13A / Out 13A 184×97×135 Plastic (Y Black)

Full Y-series black-enclosure selection details: Download the 300 Y-Series Black Enclosure Selection Manual (PDF)

Enclosure Options — S / Y / D / Z

This series offers four enclosure styles — S, Y, D and Z. For ratings up to 11 kW, all four are made of durable plastic housing, and the drive electronics inside are identical — only the housing shape, form factor and dimensions differ, so you can pick the enclosure that best fits your installation.

SHZK 300N S-Type Enclosure

S Type

Compact Enclosure

Compact, lightweight plastic housing for small power ratings — ideal for tight panel spaces.

SHZK 300N Y-Type Black Enclosure

Y Type

Black Enclosure

Black plastic moulded housing — a clean, discreet look with identical performance.

SHZK 300N D-Type Enclosure

D Type

Rugged Plastic Enclosure

Robust, rugged plastic enclosure with a sturdy industrial appearance.

SHZK 300N Z-Type Enclosure

Z Type

Standard Enclosure

Standard plastic housing with consistent performance.

Enclosure selection manuals (dimensions, panel cut-outs & terminals):

Electrical Specifications

Power Range Input Voltage Output Voltage Output Frequency
0.75kW – 3kW Single Phase 220V 50/60Hz Single Phase 0-220V 0-500Hz

Why Choose 300N H2 Series?

Single-Phase Speed Control Made Simple

Direct single-phase 220V input and output — the simplest VFD solution for small motors, no phase conversion needed.

20-25% Lower Energy Bills

Match fan and pump speed to actual demand. Perfect for HVAC, small conveyors, and packaging equipment.

Ultra-Compact Design

Smallest footprint in the 300N range. Wall-mount or DIN-rail options for tight control panels.

Budget-Friendly Entry Point

Most affordable 300N series. Ideal for OEM integration and small batch orders.

Quick Selection Guide — H2 Series

Your Application Recommended Model Key Tip
Small Fan / Blower Standard Variable torque saves energy on continuous-run fans
Small Pump Standard Built-in PID for constant pressure water supply
Packaging / Textile Machine Standard Multi-speed for different production stages
OEM Integration Custom Logo MOQ 50 units for OEM branding

Quick Specs at a Glance

Input Voltage 1PH AC 200V ~ 240V
Output Voltage 1PH AC 0 ~ 240V
Power Range 0.75kW – 3kW
Output Frequency 0 – 600Hz
Control Mode Sensorless Vector / V/F
Overload Capacity 150%/60s
Best For Single-phase motor speed control, OEM integration

Complete Technical Specifications

Parameter Specification
Output Frequency 0-500Hz
Carrier Frequency 1.0-15.0kHz, automatically adjusts based on temperature and load
Control Method Optimized space voltage vector SVPWM control
Control Mode Sensorless vector control with optimal low-frequency dead zone compensation
V/F Control Linear, multi-point, square root (selectable)
Frequency Resolution Digital setting: 0.01Hz; Analog setting: max frequency × 0.025%
Starting Frequency 0.0-10.0Hz
Starting Torque 0.5Hz / 180% (Sensorless Vector Control); 1Hz / 180% (V/F)
Torque Boost Automatic torque boost; Manual torque boost 0.1%-30.0%
Speed Control Accuracy ±0.5% of maximum speed (Sensorless Vector Control)
Speed Adjustment Range 1:100 (Sensorless Vector Control)
Overload Capacity (G-type) 150% rated current for 1 minute, 180% rated current for 3 seconds
Overload Capacity (P-type) 120% rated current for 60 seconds, 150% rated current for 10 seconds
Acceleration/Deceleration Linear or S-curve, 4 sets of accel/decel time (0.1-3600s)
DC Braking DC braking at start and stop
Jog Operation Jog frequency: 0.0Hz to max frequency; Jog accel/decel time: 0.1-3600s
Built-in PID Closed-loop control for pressure, flow, temperature regulation
Multi-speed Operation Up to 16-speed via built-in PLC or control terminals
Run Command Channel Control panel, control terminals, RS485 communication
Frequency Setting Digital keypad, analog input (AI1/AI2), RS485, multi-speed, simple PLC, PID
Digital Input 5 programmable digital inputs (DI1-DI5), DI5 supports 20kHz high-speed pulse input
Analog Input 2 channels (AI1, AI2): 0-20mA / 0-10V selectable
Analog Output 2 channels (AO1, AO2): 0-20mA or 0-10V selectable
Relay Output 2 relays: NO/NC, rated AC250V 3A / DC30V 1A
Communication RS485 Modbus RTU (standard)
Protection Overcurrent, overvoltage, undervoltage, overheat, overload, input/output phase loss, motor overheat (PTC), ground fault
Display LED display showing set frequency, output frequency, output voltage, output current, etc.
Operating Temperature -10°C to +50°C (derating above 40°C)
Storage Temperature -20°C to +60°C
Humidity ≤95% RH, non-condensing
Altitude ≤1000m (derate 1% per 100m above 1000m)
Protection Degree IP20 (standard); IP54 available on request
Installation Wall mount or flange mount
Cooling Forced air cooling
Quality Assurance 100% full-load aging test before shipment

Model Naming Convention

SHZK 300N models follow a standardized naming system for easy identification:

300N-055GB-T4

Position Code Description
Series 300N 300N Series
Motor adapter power 0.75 / 1.5 / 2.2 / 5.5 / 7.5 / 18.5 Decimal ratings are written as-is, in kW
003 / 011 / 055 / 800 Whole-number ratings use three digits: 003 = 3 kW, 011 = 11 kW, 055 = 55 kW, 800 = 800 kW
Full range 0.75 kW – 800 kW across the 300N platform
Motor type G Heavy load (constant torque) — standard industrial drives
P Fan / pump type (light duty) — used on S3 models
PV Photovoltaic DC input with CVT / MPPT tracking — PV-T2 / PV-T4
Braking Unit B With built-in braking unit
(blank) Without braking unit
Voltage Class T4 3PH AC 380-480V Input / 3PH 0-480V Output
T2 3PH AC 200-240V Input / 3PH 0-240V Output
S2 1PH AC 200-240V Input / 3PH 0-240V Output
S3 1PH AC 200-240V Input / 3PH 0-400V Output
H2 1PH AC 200-240V Input / 1PH 0-240V Output
Reactor Option (blank) No reactor
-L With AC output reactor
-T With DC reactor

Common 300N variants

Variant Meaning Used in
G Heavy load (constant torque), without built-in braking unit H2; T2 from 15 kW; T4 from 30 kW
GB Heavy load (constant torque) with built-in braking unit S2; T2 up to 11 kW; T4 up to 22 kW
PB Fan / pump type (light duty) with built-in braking unit S3, all ratings
PV Photovoltaic DC input with CVT / MPPT tracking PV-T2 / PV-T4, all ratings

Available Configurations

Configuration Model Suffix Best For
General Industrial G Conveyors, CNC, mixers, general machinery
Fan & Pump (Energy Saving) P Centrifugal pumps, HVAC fans, blowers (lower overload, optimized for variable torque loads)
Solar/PV Dedicated PV Solar water pumping, agricultural irrigation, off-grid water supply (MPPT + CVT dual-mode solar tracking)

Optional Accessories

  • Braking Unit (B): Built-in braking resistor for applications requiring fast deceleration (cranes, hoists, elevators)
  • AC Output Reactor (-L): Recommended for long motor cable runs (>50m) or multiple motors on one VFD
  • DC Reactor (-T): Improves power factor and reduces harmonic distortion for large installations
  • Communication Cards: Profibus-DP and Profinet modules available on request for SCADA integration

Applications

CNC machines, small conveyors, packaging equipment, textile machinery, and other single-phase motor control applications.

OEM & ODM available. Contact us for pricing and technical support.

Inside the 300N H2 Series: Structure, Quality & Certification

Built in our own SHZK production line, the 300N H2 Series combines a precision power stage with factory-tested reliability. Every unit is 100% full-load aged and QA-inspected before shipping.

✅ CE Certified — compliant with EU Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU. Certificate no. M.2026.206.C145141 (UDEM, valid 2026–2031). Download CE certificate →

SHZK VFD Internal Components & PCB Detail

Precision power stage — IGBT modules and a layered control PCB.

SHZK VFD Heat Sink & Power Module

Efficient cooling — finned heat sink and power module design for sustained torque.

SHZK VFD Control Board PCB

Vector control board — precise speed & torque regulation logic.

SHZK VFD Size Comparison Across Power Ratings

Scalable footprint — compare unit sizes from 1.5 kW to 11 kW and beyond.

Factory & Quality Assurance

SMT surface-mount production and 100% full-load aging before delivery — backed by CE, RoHS & ISO 9001 manufacturing.

OEM / ODM Ready

Custom branding, packaging and parameter presets from a MOQ of 50 units — for system integrators and panel builders.

Download 300N H2 Series Technical Documentation (PDF)

Control Circuit Wiring Diagrams

The following diagrams show the control circuit terminal layout and wiring for each main board type used in the 300 Series.

Main Circuit Terminal Layout

Main Circuit Terminal Layout

Main Circuit Terminal Layout (R/L1, S/L2, T — PP, PB — U, V, W — G, E)

A-Type Main Board Wiring Diagram

A-Type Main Board Wiring Diagram

Wiring Notes

  • Analog voltage signals require shielded cables; wiring distance should not exceed 20m.
  • In severe interference environments, equip analog signal source side with filter capacitor or ferrite core.
  • Terminal assignments may vary by model — refer to actual product labeling.
Inquire Now / Send Inquiry
📥 Download Resources:
Complete Catalog (PDF) |
Selection Handbook (PDF) |
Operation Manual (PDF)

Not sure which VFD fits your motor?

Share your power, voltage and load details. We’ll pick the right model and send a competitive factory quote.

Get a Quote
Explore Products