VFD 300 S2 Series

VFD 300 S2 Series – Single Phase 220V Input / Three Phase 220V Output

The VFD 300 S2 Series converts single-phase 220V input to three-phase 220V output, providing efficient motor control for applications requiring three-phase power from a single-phase supply.

Key Features

  • Output Frequency: 0-500Hz
  • Overload Capacity: 150% rated current for 1 minute, 180% for 3 seconds
  • Control Method: Optimized SVPWM control
  • Control Mode: Sensorless vector control
  • Frequency Resolution: Digital 0.01Hz; Analog max frequency ×0.025%
  • Automatic torque boost: 0.1%-30.0%
  • Built-in PID closed-loop control
  • Multi-speed operation via built-in PLC
  • RS485 communication
  • 5 programmable digital inputs, 2 analog inputs
  • 2 relay outputs
  • Full protection suite included

Model Specifications

Model Rated Current Dimensions (H×W×D mm) Shell Type
300N-0.75GB-S2 Input 8.2A / Output 4A 165×98×128 Plastic (S)
300N-1.5GB-S2 Input 14A / Output 7A 165×98×128 Plastic (S)
300N-2.2GB-S2 Input 23A / Output 9.6A 165×98×128 Plastic (S)
300N-003GB-S2 Input 27A / Output 12A 187×100×137.5 Plastic (S)
300N-004GB-S2 Input 39.7A / Output 15A 187×100×137.5 Plastic (S)
300N-5.5GB-S2 Input 41.3A / Output 13A 220×130×177.5 Plastic (S)

Electrical Specifications

Power Input Voltage Output Voltage Output Frequency Net Weight
0.75-2.2kW 3PH 220V 50/60Hz 3PH 0-220V 0-500Hz 1.24kg
3kW 3PH 220V 50/60Hz 3PH 0-220V 0-500Hz 1.8kg
4-5.5kW 3PH 220V 50/60Hz 3PH 0-220V 0-500Hz 2.85kg

Why Choose VFD300 S2 Series?

Run 3-Phase Motors on Single-Phase Power

Convert 220V single-phase to 220V three-phase — unlock industrial motor performance in residential or small workshop environments.

Compact & Easy to Install

Wall-mount design fits in tight spaces. No extra cabinets or complex wiring required.

20-30% Energy Savings

Match motor speed to actual load demand. Ideal for small pumps, fans, and light industrial equipment.

Soft Start Protection

Eliminate inrush current spikes and mechanical shock. Protect motors and reduce maintenance frequency.

Quick Selection Guide — S2 Series

Your Application Recommended Model Key Tip
Small Water Pump P Type Use built-in PID for constant pressure
Small Fan / Blower P Type Variable torque mode saves 20-30% energy
Small Conveyor / Machine Tool G Type Size up 1 level for starting torque
General Purpose G Type Default choice for mixed loads

Quick Specs at a Glance

Input Voltage 1PH AC 200V ~ 240V
Output Voltage 3PH AC 0 ~ 240V
Power Range 0.75kW – 5.5kW
Output Frequency 0 – 600Hz
Control Mode Sensorless Vector / V/F
Overload Capacity G: 150%/60s, P: 120%/60s
Best For Single-phase homes/workshops needing 3-phase motor control

Complete Technical Specifications

Parameter Specification
Output Frequency 0-500Hz
Carrier Frequency 1.0-15.0kHz, automatically adjusts based on temperature and load
Control Method Optimized space voltage vector SVPWM control
Control Mode Sensorless vector control with optimal low-frequency dead zone compensation
V/F Control Linear, multi-point, square root (selectable)
Frequency Resolution Digital setting: 0.01Hz; Analog setting: max frequency × 0.025%
Starting Frequency 0.0-10.0Hz
Starting Torque 0.5Hz / 180% (Sensorless Vector Control); 1Hz / 180% (V/F)
Torque Boost Automatic torque boost; Manual torque boost 0.1%-30.0%
Speed Control Accuracy ±0.5% of maximum speed (Sensorless Vector Control)
Speed Adjustment Range 1:100 (Sensorless Vector Control)
Overload Capacity (G-type) 150% rated current for 1 minute, 180% rated current for 3 seconds
Overload Capacity (P-type) 120% rated current for 60 seconds, 150% rated current for 10 seconds
Acceleration/Deceleration Linear or S-curve, 4 sets of accel/decel time (0.1-3600s)
DC Braking DC braking at start and stop
Jog Operation Jog frequency: 0.0Hz to max frequency; Jog accel/decel time: 0.1-3600s
Built-in PID Closed-loop control for pressure, flow, temperature regulation
Multi-speed Operation Up to 16-speed via built-in PLC or control terminals
Run Command Channel Control panel, control terminals, RS485 communication
Frequency Setting Digital keypad, analog input (AI1/AI2), RS485, multi-speed, simple PLC, PID
Digital Input 5 programmable digital inputs (DI1-DI5), DI5 supports 20kHz high-speed pulse input
Analog Input 2 channels (AI1, AI2): 0-20mA / 0-10V selectable
Analog Output 2 channels (AO1, AO2): 0-20mA or 0-10V selectable
Relay Output 2 relays: NO/NC, rated AC250V 3A / DC30V 1A
Communication RS485 Modbus RTU (standard)
Protection Overcurrent, overvoltage, undervoltage, overheat, overload, input/output phase loss, motor overheat (PTC), ground fault
Display LED display showing set frequency, output frequency, output voltage, output current, etc.
Operating Temperature -10°C to +50°C (derating above 40°C)
Storage Temperature -20°C to +60°C
Humidity ≤95% RH, non-condensing
Altitude ≤1000m (derate 1% per 100m above 1000m)
Protection Degree IP20 (standard); IP54 available on request
Installation Wall mount or flange mount
Cooling Forced air cooling
Quality Assurance 100% full-load aging test before shipment

Model Naming Convention

SHZK VFD300 models follow a standardized naming system for easy identification:

XXX – 055 G B – T4 – L

Position Code Description
Series 300 VFD300 Series
Power Rating 007 0.75 kW
015 1.5 kW
055 5.5 kW
720 72 kW
800 80 kW
Motor Type G General purpose (standard industrial)
P Fan & Pump type (light-duty, 120% overload)
PV Solar/PV dedicated (MPPT/CVT solar tracking)
Braking Unit B With built-in braking unit
(blank) Without braking unit
Voltage Class T4 3PH AC 380-480V Input / 3PH 0-480V Output
T2 3PH AC 200-240V Input / 3PH 0-240V Output
S2 1PH AC 200-240V Input / 3PH 0-240V Output
S3 1PH AC 200-240V Input / 3PH 0-400V Output
H2 1PH AC 200-240V Input / 1PH 0-240V Output
Reactor Option (blank) No reactor
-L With AC output reactor
-T With DC reactor

Available Configurations

Configuration Model Suffix Best For
General Industrial G Conveyors, CNC, mixers, general machinery
Fan & Pump (Energy Saving) P Centrifugal pumps, HVAC fans, blowers (lower overload, optimized for variable torque loads)
Solar/PV Dedicated PV Solar water pumping, agricultural irrigation, off-grid water supply (MPPT + CVT dual-mode solar tracking)

Optional Accessories

  • Braking Unit (B): Built-in braking resistor for applications requiring fast deceleration (cranes, hoists, elevators)
  • AC Output Reactor (-L): Recommended for long motor cable runs (>50m) or multiple motors on one VFD
  • DC Reactor (-T): Improves power factor and reduces harmonic distortion for large installations
  • Communication Cards: Profibus-DP and Profinet modules available on request for SCADA integration

Applications

Conveyor systems, fans, pumps, machine tools, and industrial equipment requiring three-phase power from single-phase supply.

OEM & ODM available. Contact us for pricing and technical support.

Control Circuit Wiring Diagrams

The following diagrams show the control circuit terminal layout and wiring for each main board type used in the 300 Series.

Main Circuit Terminal Layout

Main Circuit Terminal Layout

Main Circuit Terminal Layout (R/L1, S/L2, T — PP, PB — U, V, W — G, E)

A-Type Main Board Wiring Diagram

A-Type Main Board Wiring Diagram

Wiring Notes

  • Analog voltage signals require shielded cables; wiring distance should not exceed 20m.
  • In severe interference environments, equip analog signal source side with filter capacitor or ferrite core.
  • Terminal assignments may vary by model — refer to actual product labeling.
Inquire Now / Send Inquiry
📥 Download Resources:
Complete Catalog (PDF) |
Selection Handbook (PDF) |
Operation Manual (PDF)