VFD 300 PV-T2 Series

VFD 300 PV-T2 Series – Three Phase 380V Input / Three Phase 380V Output

The VFD 300 PV-T2 Series is our solar PV dedicated variable frequency drive with DC input support, featuring MPPT/CVT dual-mode solar power tracking, covering power range from 0.75kW to 75kW. Featuring advanced vector control technology, it delivers precise motor control for demanding industrial applications.

Key Features

  • Output Frequency: 0-500Hz
  • Overload Capacity: 150% rated current for 1 minute, 180% for 3 seconds
  • Control Method: Optimized space voltage vector SVPWM control
  • Control Mode: Sensorless vector control with optimal low-frequency dead zone compensation
  • Frequency Resolution: Digital 0.01Hz; Analog max frequency ×0.025%
  • Starting Frequency: 0.0-10.0Hz
  • Torque Boost: Automatic / Manual 0.1%-30.0%
  • Built-in PID closed-loop control
  • Multi-speed operation via built-in PLC or control terminals
  • RS485 communication support
  • PV Power Tracking: CVT mode, MPPT mode
  • Comprehensive protection: overcurrent, overvoltage, undervoltage, overheat, overload

Model Specifications

Model Rated Current Dimensions (H×W×D mm) Shell Type
PV-300N-0.75GB-T2 Input 4.5A / Output 4A 165×98×128 Plastic (S)
PV-300N-1.5GB-T2 Input 8A / Output 7A 165×98×128 Plastic (S)
PV-300N-2.2GB-T2 Input 11A / Output 9.6A 165×98×128 Plastic (S)
PV-300N-003GB-T2 Input 15A / Output 12A 165×98×128 Plastic (S)
PV-300N-004GB-T2 Input 23A / Output 15A 187×100×137.5 Plastic (S)
PV-300N-5.5GB-T2 Input 28A / Output 17A 187×100×137.5 Plastic (S)
PV-300N-7.5GB-T2 Input 36A / Output 25A 220×130×177.5 Plastic (S)
PV-300N-011G-T2 Input 50A / Output 32A 280×150×196 Iron
PV-300N-015G-T2 Input 65A / Output 41A 280×150×196 Iron
PV-300N-018G-T2 Input 76A / Output 50A 280×150×196 Iron
PV-300N-022G-T2 Input 88A / Output 60A 330×170×235 Iron
PV-300N-030G-T2 Input 120A / Output 80A 380×215×215 Iron
PV-300N-037G-T2 Input 150A / Output 100A 380×215×215 Iron
PV-300N-045G-T2 Input 180A / Output 120A 510×260×260 Iron
PV-300N-055G-T2 Input 210A / Output 150A 510×260×260 Iron
PV-300N-075G-T2 Input 239A / Output 253A 535×260×272 Iron

Electrical Specifications

Parameter Specification
Input Voltage DC 170-450V / Three Phase 220V 50/60Hz
Output Voltage Three Phase 0-220V
Output Frequency 0-500Hz
Operating Voltage Three-phase 220V Input / Three-phase 0-220V Output

Plastic Shell: Compact design for 0.75kW-7.5kW models
Iron Shell: Enhanced durability for 11kW-75kW models

SHZK VFD300 PV-T2 Series Large Power Unit Side View 44kW-55kW
SHZK VFD300 PV-T2 Series Large Power Unit Front View 44kW-55kW

Why Choose VFD300 PV-T2 Series?

Up to 30% Energy Savings

Variable speed control eliminates energy waste from constant-speed motors. ROI typically achieved within 12-18 months.

Zero Grid? No Problem (PV Mode)

MPPT/CVT dual-mode solar tracking drives pumps directly from panels — no batteries, no grid connection needed.

50% Less Maintenance Cost

Soft start/stop eliminates mechanical stress on pumps, conveyors, and fans. Extended equipment lifespan.

Built for Harsh Environments

IP20/IP54 options, -10°C to 50°C operation, coated PCBs. Deploy in mines, farms, and factories worldwide.

Quick Selection Guide — T2 Series

Your Application Recommended Model Key Tip
Solar Water Pump PV Type Oversize PV array by 20-30%; use MPPT mode
Water Pump / HVAC P Type Variable torque; PID built-in for pressure control
Conveyor / Mixer / Crusher G Type Constant torque; size up 1 level for heavy loads
CNC Spindle G Type High frequency resolution 0.01Hz; braking unit recommended
High Altitude (>1000m) Derate 1%/100m Above 4000m, contact our engineers for customization

Quick Specs at a Glance

Input Voltage 3PH AC 380V (-15%) ~ 440V (+10%)
Output Voltage 3PH AC 0 ~ 440V
Power Range 0.75kW – 800kW
Output Frequency 0 – 600Hz
Control Mode Sensorless Vector / V/F
Overload Capacity G: 150%/60s, P: 120%/60s
Protection OC, OV, UV, OH, OL, Phase Loss, Ground Fault
Special Feature MPPT/CVT Solar Tracking (PV Type)

Complete Technical Specifications

Parameter Specification
Output Frequency 0-500Hz
Carrier Frequency 1.0-15.0kHz, automatically adjusts based on temperature and load
Control Method Optimized space voltage vector SVPWM control
Control Mode Sensorless vector control with optimal low-frequency dead zone compensation
V/F Control Linear, multi-point, square root (selectable)
Frequency Resolution Digital setting: 0.01Hz; Analog setting: max frequency × 0.025%
Starting Frequency 0.0-10.0Hz
Starting Torque 0.5Hz / 180% (Sensorless Vector Control); 1Hz / 180% (V/F)
Torque Boost Automatic torque boost; Manual torque boost 0.1%-30.0%
Speed Control Accuracy ±0.5% of maximum speed (Sensorless Vector Control)
Speed Adjustment Range 1:100 (Sensorless Vector Control)
Overload Capacity (G-type) 150% rated current for 1 minute, 180% rated current for 3 seconds
Overload Capacity (P-type) 120% rated current for 60 seconds, 150% rated current for 10 seconds
Acceleration/Deceleration Linear or S-curve, 4 sets of accel/decel time (0.1-3600s)
DC Braking DC braking at start and stop
Jog Operation Jog frequency: 0.0Hz to max frequency; Jog accel/decel time: 0.1-3600s
Built-in PID Closed-loop control for pressure, flow, temperature regulation
Multi-speed Operation Up to 16-speed via built-in PLC or control terminals
Run Command Channel Control panel, control terminals, RS485 communication
Frequency Setting Digital keypad, analog input (AI1/AI2), RS485, multi-speed, simple PLC, PID
Digital Input 5 programmable digital inputs (DI1-DI5), DI5 supports 20kHz high-speed pulse input
Analog Input 2 channels (AI1, AI2): 0-20mA / 0-10V selectable
Analog Output 2 channels (AO1, AO2): 0-20mA or 0-10V selectable
Relay Output 2 relays: NO/NC, rated AC250V 3A / DC30V 1A
Communication RS485 Modbus RTU (standard)
Protection Overcurrent, overvoltage, undervoltage, overheat, overload, input/output phase loss, motor overheat (PTC), ground fault
PV Power Tracking CVT mode, MPPT mode
Display LED display showing set frequency, output frequency, output voltage, output current, etc.
Operating Temperature -10°C to +50°C (derating above 40°C)
Storage Temperature -20°C to +60°C
Humidity ≤95% RH, non-condensing
Altitude ≤1000m (derate 1% per 100m above 1000m)
Protection Degree IP20 (standard); IP54 available on request
Installation Wall mount or flange mount
Cooling Forced air cooling
Quality Assurance 100% full-load aging test before shipment

Model Naming Convention

SHZK VFD300 models follow a standardized naming system for easy identification:

XXX – 055 G B – T4 – L

Position Code Description
Series 300 VFD300 Series
Power Rating 007 0.75 kW
015 1.5 kW
055 5.5 kW
720 72 kW
800 80 kW
Motor Type G General purpose (standard industrial)
P Fan & Pump type (light-duty, 120% overload)
PV Solar/PV dedicated (MPPT/CVT solar tracking)
Braking Unit B With built-in braking unit
(blank) Without braking unit
Voltage Class T4 3PH AC 380-480V Input / 3PH 0-480V Output
T2 3PH AC 200-240V Input / 3PH 0-240V Output
S2 1PH AC 200-240V Input / 3PH 0-240V Output
S3 1PH AC 200-240V Input / 3PH 0-400V Output
H2 1PH AC 200-240V Input / 1PH 0-240V Output
Reactor Option (blank) No reactor
-L With AC output reactor
-T With DC reactor

Available Configurations

Configuration Model Suffix Best For
General Industrial G Conveyors, CNC, mixers, general machinery
Fan & Pump (Energy Saving) P Centrifugal pumps, HVAC fans, blowers (lower overload, optimized for variable torque loads)
Solar/PV Dedicated PV Solar water pumping, agricultural irrigation, off-grid water supply (MPPT + CVT dual-mode solar tracking)

Optional Accessories

  • Braking Unit (B): Built-in braking resistor for applications requiring fast deceleration (cranes, hoists, elevators)
  • AC Output Reactor (-L): Recommended for long motor cable runs (>50m) or multiple motors on one VFD
  • DC Reactor (-T): Improves power factor and reduces harmonic distortion for large installations
  • Communication Cards: Profibus-DP and Profinet modules available on request for SCADA integration

Applications

Heavy industry, mining equipment, large conveyors, HVAC systems, water treatment, oil & gas, manufacturing lines, and PV solar pump systems.

OEM & ODM available. Contact us for pricing and technical support.

Control Circuit Wiring Diagrams

The following diagrams show the control circuit terminal layout and wiring for each main board type used in the 300 Series. The board type varies by model and power rating.

Main Circuit Terminal Layout

Main Circuit Terminal Layout

Main Circuit Terminal Layout (R/L1, S/L2, T — PP, PB — U, V, W — G, E)

A-Type (0.75-11kW) Main Board Wiring Diagram

A-Type Board Wiring

B-Type (Mid Power) Main Board Wiring Diagram

B-Type Board Wiring

C-Type (Mid Power) Main Board Wiring Diagram

C-Type Board Wiring

D-Type (High Power) Main Board Wiring Diagram

D-Type Board Wiring

E-Type (Max Power) Main Board Wiring Diagram

E-Type Board Wiring

Wiring Notes

  • Analog voltage signals require shielded cables; wiring distance should not exceed 20m.
  • In severe interference environments, equip analog signal source side with filter capacitor or ferrite core.
  • Terminal assignments may vary by model — refer to actual product labeling.
Inquire Now / Send Inquiry

FAQ About VFD 300 PV-T2 Series

What is the difference between VFD, AC drive, and frequency inverter?

VFD (Variable Frequency Drive), AC drive, and frequency inverter are different names for the same device. They all control the speed of an AC motor by varying the frequency and voltage of the power supplied. “VFD” is most common in North America, “AC drive” is widely used globally, and “frequency inverter” is common in Europe and Southeast Asia.

What applications is the N/T series suitable for?

The N/T series three-phase VFD is ideal for pumps, fans, HVAC systems, air compressors, conveyors, mixers, crushers, and other industrial equipment requiring precise speed control and energy savings.

How to choose the right VFD for my motor?

Match the VFD rated power to your motor power rating. For pump and fan applications, you can often use a VFD one size smaller. For constant torque loads like conveyors, match exactly. Consider input voltage, output current, and application requirements. Contact our technical team for sizing assistance.

Related Products

📥 Download Resources:
Complete Catalog (PDF) |
Selection Handbook (PDF) |
Operation Manual (PDF)